Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Lab Med ; 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38507614

RESUMO

BACKGROUND: During the COVID-19 pandemic, many molecular diagnostic laboratories performed high-throughput SARS-CoV-2 testing often with implementation of automated workflows. In parallel, vaccination campaigns resulted increasingly in specimens from fully vaccinated patients, with resultant clinical inquiries regarding positive results in this patient population. This prompted a quality improvement initiative to investigate the semi-automated testing workflow for false-positive results. The troubleshooting workflow is described and procedural improvements are outlined that serve as a resource for other molecular diagnostic laboratories that need to overcome testing anomalies in a semi-automated environment. METHODS: This workflow utilized the MagMax-96 Viral RNA kit and the CDC 2019-nCoV RT-qPCR Panel on the Agilent Bravo Liquid-Handler (Bravo). Screening of the environment, personnel, and the mechanical performance of instrumentation using low Ct checkerboard challenges was executed to identify sources of cross-contamination. Evaluation of the assay and reporting design was conducted. RESULTS: Specimen contamination was observed during the viral extraction process on the Bravo. Changes to the program reduced plate contamination by 50% and importantly revealed consistent hallmarks of contaminated samples. We adjusted the reporting algorithm using these indicators of false positives. False positives that were identified made up 0.11% of the 45 000+ tests conducted over the following 8 months. CONCLUSIONS: These adjustments provided confident and quality results while maintaining turnaround time for patients and pandemic-related public health initiatives. This corrected false-positive rate is concordant with previously published studies from diagnostic laboratories utilizing automated systems and may be considered a laboratory performance standard for this type of testing.

2.
Carcinogenesis ; 42(12): 1428-1438, 2021 12 31.
Artigo em Inglês | MEDLINE | ID: mdl-34849607

RESUMO

Serine/Threonine Kinase 11 (STK11) encodes an important tumor suppressor that is frequently mutated in lung adenocarcinoma. Clinical studies have shown that mutations in STK11 resulting in loss of function correlate with resistance to anti-PD-1 monoclonal antibody therapy in KRAS-driven non-small cell lung cancer (NSCLC), but the molecular mechanisms responsible remain unclear. Despite this uncertainty, STK11 functional status is emerging as a reliable biomarker for predicting non-response to anti-PD-1 therapy in NSCLC patients. The clinical utility of this biomarker ultimately depends upon accurate classification of STK11 variants. For nonsense variants occurring early in the STK11 coding region, this assessment is straightforward. However, rigorously demonstrating the functional impact of missense variants remains an unmet challenge. Here we present data characterizing four STK11 splice-site variants by analyzing tumor mRNA, and 28 STK11 missense variants using an in vitro kinase assay combined with a cell-based p53-dependent luciferase reporter assay. The variants we report were identified in primary human NSCLC biopsies in collaboration with the University of Vermont Genomic Medicine group. Additionally, we compare our experimental results with data from 22 in silico predictive algorithms. Our work highlights the power, utility and necessity of functional variant assessment and will aid STK11 variant curation, provide a platform to assess novel STK11 variants and help guide anti-PD-1 therapy utilization in KRAS-driven NSCLCs.


Assuntos
Quinases Proteína-Quinases Ativadas por AMP/genética , Carcinoma Pulmonar de Células não Pequenas/genética , Neoplasias Pulmonares/genética , Mutação , Quinases Proteína-Quinases Ativadas por AMP/metabolismo , Processamento Alternativo , Biomarcadores Tumorais , Sistemas CRISPR-Cas , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/mortalidade , Análise Mutacional de DNA , Suscetibilidade a Doenças , Edição de Genes , Regulação Neoplásica da Expressão Gênica , Predisposição Genética para Doença , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/mortalidade , Mutagênese Sítio-Dirigida , Mutação de Sentido Incorreto , Fosforilação , Prognóstico , Sítios de Splice de RNA
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...